Bright Haven Electric LLC

Bright Haven Electric LLC
Grounded in Reliability, Powered by Expertise
Home » Electrical Services » Off-Peak Heating & Energy Management » Load Management Receivers & Off-Peak Wiring MN » EV Charger & Off-Peak Load Control Installation – Canby, MN

EV Charger & Off-Peak Load Control Installation – Canby, MN

When Marcus in Canby, Minnesota decided to add a dedicated 50-amp EV charger outlet in his garage, the project turned out to involve a lot more than just running a wire. His home was already set up with an Otter Tail Power off-peak electric water heater controlled by a utility load control radio receiver. Adding a high-draw EV charger circuit meant we needed to redesign the load control system, migrate the water heater, prep the main panel for the new breaker, and coordinate directly with the utility company – all before we could install the outlet itself.

This is the kind of project where experience with utility coordination, load management systems, and NEC code compliance really matters. Here’s how we handled it.

The Starting Point

Marcus’s home had a dual meter base on the exterior wall – one for the main house service and one for the off-peak water heater. The existing Otter Tail Power Comverge load control receiver was mounted on the wall between the meters, controlling when the water heater could draw power based on the utility’s off-peak rate schedule.

Exterior dual electric meter base and utility load control receiver before EV charger installation in Canby MN
The original exterior setup – dual Milbank meter bases with the Otter Tail Power Comverge load control receiver mounted between them.

To add the EV charger, we couldn’t just throw a 50-amp breaker in the panel and call it done. The water heater had to be migrated off its separate meter and onto the main panel, the load control receiver needed to be relocated into a proper outdoor enclosure with contactors to switch both the water heater and the new EV circuit, and the panel itself needed space preparation and new breakers.

Custom Dual-Contactor Load Control Enclosure

The centerpiece of this installation was a custom-built outdoor NEMA 3R isolation enclosure mounted directly below the electric meters on the exterior wall. Inside, we installed two commercial-grade definite purpose contactors:

  • 60A Square D Contactor (EV Charger) – Controls the 50-amp EV charger circuit, allowing the utility to shed the EV load during peak demand periods.
  • 40A Honeywell Contactor (Water Heater) – Controls the migrated electric water heater circuit under the same off-peak rate program.

Both contactors are driven by the Otter Tail Power Comverge radio receiver, which sends signals from the utility to cycle loads on and off during peak hours. By mounting the enclosure back-to-back with the interior main panel, all switching loops and control wiring route straight through a single wall penetration – keeping everything grouped per NEC 300.3(B) and making the entire system clean, accessible, and easy to service.

Dual contactor NEMA 3R enclosure with 60A EV charger and 40A water heater contactors for off-peak load control
Inside the NEMA 3R isolation enclosure – 60A Square D contactor (EV charger) and 40A Honeywell contactor (water heater) with control wiring connected to the utility load control receiver.
Completed outdoor NEMA 3R load control enclosure wired to Comverge utility receiver
The completed outdoor enclosure fully wired and connected to the Otter Tail Power Comverge receiver, ready for service.

Panel Prep and Wiring

Inside the house, the Square D QO load center got a full workup. We installed the new 50-amp EV charger breaker, migrated the water heater circuit from its old separate disconnect onto the main panel, and added a dedicated 2-pole 15A control power breaker to supply the contactor coils in the outdoor enclosure. Three liquidtight flexible conduit runs were routed cleanly down the backboard to carry the switched EV feed, the switched water heater feed, and the control circuit through the wall to the outdoor NEMA 3R box.

Square D electrical panel wired for EV charger circuit and off-peak load control in Canby MN
Square D QO load center with the new EV charger breaker, migrated water heater circuit, and three liquidtight conduit runs routed to the outdoor contactor enclosure.
Finished electrical panel with three parallel liquidtight conduit runs for EV charger installation
The finished panel with deadfront installed and three parallel liquidtight conduit runs neatly strapped to the backboard.

The 50A NEMA 14-50 EV Charger Outlet

The final piece was the outlet itself – a dedicated 50-amp NEMA 14-50 receptacle installed in the garage on a surface-mount metal box with a painted conduit run. This is the same outlet type used by Tesla, ChargePoint, and most other Level 2 EV chargers. Marcus supplied his own charger, so we provided the dedicated circuit and receptacle ready to plug in and go.

50 amp NEMA 14-50 EV charger outlet installed in garage in Canby MN
Dedicated 50A NEMA 14-50 receptacle for EV charging – surface-mounted in the garage with a clean painted conduit run.

Utility Coordination and Off-Peak Savings

A big part of this project was working directly with Otter Tail Power’s load management team to make sure the new contactor system met their program requirements. By enrolling the EV charger in the off-peak load control program alongside the water heater, Marcus qualifies for Otter Tail’s off-peak rebate – which helps offset the installation cost and lowers his ongoing electricity rates for EV charging.

We also designed the contactor layout and wiring to be forward-compatible with Otter Tail Power’s upcoming Landis & Gyr radio receiver rollout, so when the utility upgrades their equipment in the future, the transition will be straightforward.

What the Customer Had to Say

“Chad did an awesome job installing my EV charger in my garage. From the beginning, he kept me updated, showed up when he said he would, and made the whole process easy. The quality of his work is top-notch. You can tell he takes pride in what he does. Everything was done by the book, and he doesn’t cut corners. It’s hard to find someone who cares that much about doing the job right. One thing I really appreciated was how upfront he was with pricing. His quote was accurate, and there were no surprise charges or hidden costs at the end. I wouldn’t hesitate to recommend Chad to anyone. If you’re looking for an electrician who is honest, communicates well, stands behind his work, and delivers quality craftsmanship, he’s the one to call.”

– Marcus M., Canby, MN (5-star Google review)

EV Charger Installation in West Central Minnesota

Bright Haven Electric installs dedicated EV charger circuits, NEMA 14-50 outlets, and hardwired Level 2 charging stations for homes throughout West Central Minnesota. We handle the full scope – from panel capacity evaluation and utility coordination through final state electrical inspection.

If you’re looking to add EV charging at your home in the Canby, Granite Falls, Marshall, Montevideo, Willmar, or surrounding Yellow Medicine County area, contact us online or call (320) 321-9699 for a free consultation.

About the Author

Chadwick Ferguson

Chadwick Ferguson is the owner and licensed Master Electrician behind Bright Haven Electric LLC, serving West Central Minnesota from his base in Milan, MN. With deep expertise in residential, commercial, and agricultural electrical systems, he specializes in modern energy solutions including Level 2 EV charger installations, automatic standby generators, and comprehensive electrical panel upgrades.

Chadwick is committed to providing safe, code-compliant, and reliable electrical work to his rural Minnesota community. As the author of the BHElectric blog, he shares practical insights and expert guidance to help homeowners and businesses navigate the complexities of their electrical systems.